Solved issues in version 2021.1
- The PowerMic Web Extension installation prompt is no longer displayed in Microsoft Edge. [DNB-32415]
- Recording can no longer be started when a page is opened that has no supported speech recognition fields or voice commands. [DNB-33790]
Using HTML5 content-editable elements
You can speech-enable <div> elements by adding the HTML5 contenteditable attribute.
Because the mapping of GUI text and selection points to HTML code is ambiguous, Dragon Medical SpeechKit needs to remove sources of ambiguity to ensure that recognized text is not inserted in an unexpected location.
During the initialization of speech-enabled edit controls, when you call NUSA_initialize(), NUSA_initializeVuiForm() or NUSA_reinitializeVuiForm(), the HTML content of contenteditable elements is normalized as follows:
- All comments are removed from the HTML content.
- All whitespace that is not displayed on the control's GUI is removed from the HTML content.
- In Microsoft Internet Explorer 11, if necessary, some text can be wrapped in
<div>elements. - Empty paragraphs (that the user cannot see or navigate to) are removed.
HTML element handling in a content-editable <div>
When speech-enabling a content-editable <div>, Dragon Medical SpeechKit interprets the HTML content as a sequence of plain text.
The following HTML elements have limited support when they occur in this text:
<br><p><div><h1-6><span><img>- Inline text-formatting elements such as
<b>,<i>,<strong>
These elements do not prevent speech recognition functionality, but when the user deletes or overwrites text within the content-editable <div>, these elements can also be deleted/overwritten along with any style attributes applied to them. When this occurs, voice commands such as undo that can restore deleted text but cannot restore deleted HTML elements (except for <p> and <br> elements).
Using any HTML elements not listed above causes incorrect word and selection detection and makes the content-editable <div> unusable for speech recognition.
Paragraph structure in a content-editable <div>
Dragon Medical SpeechKit inserts recognition results into a <p> element. When the user says new paragraph, a new <p> element is created and the text cursor is moved into it.
Programmatically adding text or HTML elements between paragraphs is not supported; this causes incorrect word and selection detection and makes the content-editable <div> unusable for speech recognition.
Important information
- Web browsers on mobile operating systems are not supported.
- Dragon Medical SpeechKit 2021.1 (Browser edition) requires Dragon Medical Server 3.5, 3.6 Release 2, 2020.1 and 2020.4.
- Dragon Medical Server 2020.4 is compatible with Browser editions 3.4, 3.5, 2020.1, and 2020.3.
- Filtering auto-texts (defining filters to deactivate auto-texts selectively) is deprecated and will no longer work.
- Do not change or hide Browser edition GUI elements. Changing or hiding these elements risks the stability and compatibility of the product; Nuance cannot provide support for such integrations.
- Do not embed or float the speech bar dynamically. In Microsoft Internet Explorer 11, moving the speech bar to a different container during recording briefly stops and restarts the recording.
- Web browser debugging consoles or debugging proxies (for example, Fiddler) cannot be used with speech recognition. The performance impact incurred by such infrastructure leads to unreliable speech recognition.
Supported edit controls
- All HTML
<input>and<textarea>controls. - CKEditor instances.
Note: With CKEditor 5, only the inline editor is supported.
<div>elements that have the HTML5contenteditableattribute set totrue.
Known issues
- In Google Chrome and Mozilla Firefox the page must be refreshed if the microphone is unplugged and plugged in again. [DNB-4123, DNB-18532]
Infrastructure
Infrastructure no longer supported
- Dragon Medical SpeechKit and Dragon Medical Embedded 2021.1 applications do not work with version 3.4 servers.
- Version 3.3 client applications do not work with version 2021.1 servers.
- Microsoft Windows Embedded Standard 7 is no longer supported.
Infrastructure changes planned for the next release
- Dragon Medical SpeechKit and Dragon Medical embedded 2021.2 and higher will not work with version 3.5 servers.
- Version 3.4 client applications will not work with version 2021.2 servers.
System requirements
Supported browsers
| Component | Recommended | Supported |
|---|---|---|
| Google Chrome | 89 | 87-89 |
| Mozilla Firefox* | 88 | 68-88 |
| Microsoft Internet Explorer on Windows** | - | 10-11 |
| Microsoft Edge | 90 | 42, 44, 79, 90 |
| Microsoft Silverlight | 5.1 | 5 - 5.1 |
| Apple Safari on macOS*** | 14.0.3 | 11.0.3 - 14.0.3 |
* Firefox for macOS is only supported with an external microphone.
** Internet Explorer is only supported with the Compatibility View and Protected Mode disabled. Additionally, some <!doctype> definitions are not supported; use <!doctype html>. Dragon Medical SpeechKit (Browser edition) only supports Internet Explorer 10 on platforms for which Internet Explorer 11 is not made available by Microsoft.
*** For more information, see the 'Known issues' section above.
Virtualized environments
| Component | Recommended | Supported |
|---|---|---|
| Nuance PowerMic Extension: Client | 29.2.40.0 or higher | |
| Nuance PowerMic Extension: Server and virtual desktop | 29.2.40.0 or higher | |
| Citrix XenApp | 7.15 or higher | |
| Citrix XenDesktop | 7.15 or higher | |
| Citrix client | Citrix Receiver 4.10.1 or higher Citrix Workspace app 18.9 or higher | |
| VMware Horizon View and VMware Horizon RDSH | Blast Extreme | 7.6 or higher Protocols: Blast Extreme, PCoIP |
| VMware Horizon View Agent | 7.6 or higher | |
| VMware Horizon View Client | 4.9 or higher | |
| Remote Desktop Services | Windows Server 2019 | Windows Server 2012 R2 Windows Server 2016 Windows Server 2019 |
| Remote Desktop Client | Windows 10 | Windows 8 Windows 8.1 Windows 10 |
| Remote Desktop Protocol | 7.0 or higher | |
| Linux thin clients | IGEL (For information on supported IGEL thin clients, see: http://edocs.igel.com/index.htm#10204052.htm) Fujitsu Futro S450 (operating system version eLux RP 4.9.0) Fujitsu Futro S520, S700, S720 (operating system version eLux RP 5.1) HP t610 (operating system version eLux RP 4.4.0) |
Audio configuration in virtualized environments
Hardware and software requirements depend on the audio system and configuration. Supported audio systems are listed below:
| Component | Audio system | Configuration | Bandwidth requirements |
|---|---|---|---|
| Citrix environments | HDX audio | Audio quality must be set to high (Citrix XenApp default: medium) | 150 kbit/sec |
| USB redirection | Nuance-hosted systems: Full audio and button control support* On-premises systems: Audio support only | 400 kbit/sec | |
| VMware environments | Real-Time Audio-Video (RTAV) | Default | 200 kbit/sec or higher |
| USB redirection | Nuance-hosted systems: Full audio and button control support* On-premises systems: Audio support only | 1.4 Mbit/sec | |
| RDS environments | RDS audio | Default | Approximately 1.4 Mbit/sec |
* With USB redirection, button events are forwarded automatically; the Nuance PowerMic Extension is not required.
Supported microphones
Dragon Medical SpeechKit requires a microphone which records audio data with a bit depth of 16-bit and a sampling rate of at least 16 kHz.
Nuance-hosted systems only: Support for button controls is listed below:
| Component | Local browser | Citrix XenApp | Citrix XenDesktop | RDS | VMware Horizon View |
|---|---|---|---|---|---|
| Nuance PowerMic II | yes* | yes** | yes** | yes** | yes** |
| Nuance PowerMic III | yes* | yes** | yes** | yes** | yes** |
* Your application must be running in Google Chrome on a Windows operating system. The Nuance PowerMic Web Extensions must be installed in Google Chrome and the Nuance PowerMic Web Adapter must be running on the operating system.
** Your application must be running in Google Chrome on a Windows operating system. The Nuance PowerMic Web Extensions must be installed in Google Chrome and the Nuance PowerMic Web Adapter must be running on the operating system. The Nuance PowerMic Citrix/RDS/VMware Client Extension must be installed on the client endpoint and the corresponding Nuance PowerMic Citrix/RDS/VMware Server & Virtual Desktop Extension must be installed on the server/virtual desktop where your browser application is running.
Remarks
- For more information on virtualized environments, see the Docs & Guidelines folder of the Nuance virtual extensions package on the Nuance Healthcare Development Platform.
- Dragon Medical SpeechKit (Browser edition) does not work with the Nuance Citrix/RDS/VMware Virtual Audio Extensions; the virtualized environment's native audio channels must be used.
- Citrix environments: Make sure you uninstall the Nuance PowerMic Web Extension before installing the latest version. For more information, see the Nuance PowerMic Web Extension Deployment Guide.
End-of-life: third party environments
Support for third party environments is only valid as long as they are supported by the corresponding vendor and might be subject to other restrictions. Please contact Nuance Technical Support for details. For more information, see the documentation delivered with the third party product and supporting Nuance documentation.
When standard support by the vendor has stopped, Nuance will continue support if an issue is specific to the Nuance solution, within the limitations of the vendor's standard end-of-life and Nuance's policy. This means that issues that are a combination of the vendor’s component and the Nuance solution cannot be supported.
Dragon Medical SpeechKit product life cycle
Nuance provides support throughout the life cycle of one version and point release. Please note that Nuance will not perform problem analysis after the scheduled start of restricted maintenance. Dragon Medical Server versions released over three months after the dates stated here will not work with these client editions.
| Browser edition | 3.4 | 2020.1 | 2021.1 |
|---|---|---|---|
| Restricted maintenance (scheduled start) | 2020-03-05 | 2021-05-31 | 2022-04-30 |