New in version 2022.3 (4.2 R3)
- Windows 11 is now supported. [HCPLAT-2379]
- Deferred correction: All integrators using deferred correction must start using document tokens for authentication. For information on using the document tokens authentication mechanism, see the Dragon Medical SpeechKit SDK Help ("Concepts" book, "Deferred correction" chapter, "Document tokens" section). [DNB-42903]
- Olympus devices are no longer supported. They can still be used for recording, but full button support is no longer available.
Solved in version 2022.3 (4.2 R3)
- Improved error logging: In addition to general information on the error, Dragon Medical SpeechKit client logs now include the specific error messages displayed on the UI. Log lines start with
Speechbar feedback message. [DMOCE-525] - Dragon Medical SpeechKit now loads the necessary audio libraries when the COM SDK libraries are moved to a non-standard folder. [DMOCE-1419]
- VMware and RDS environments: The speech bar no longer takes a long time to load and no longer loads with an internal audio error message the first time the user starts recording. [DMOCE-1284]
- Virtualized applications: Dragon Medical SpeechKit no longer displays an internal audio error message when the screensaver or lock screen starts during recording or playback. [DMOCE-1469]
- When the audio device is unavailable and the UI language is not English, the localized error message is now displayed. The application does not display a blank message box. [DMOCE-1422]
Known issues
- When working with a Philips SpeechMike or Nuance PowerMic 4 device, the screen saver might not be displayed after the configured period of inactivity when recording is in standby mode. To disable this behavior, press-and-hold the left mouse and touchpad buttons on the recording device for five seconds. When the firmware setting has been changed successfully, the device provides visual and audio feedback. This setting is stored on the device and needs to be changed individually on each device. [CAVE-6152]
- Plugins do not load in the personalization and help window in Citrix environments when Microsoft Edge WebView2 is installed on the Citrix server/virtual desktop. [SOD-36343]
- Connecting two different control devices at the same time is not supported. Button presses might not map to the expected actions. [CAVE-6093]
Important information
- Starting with Citrix Virtual Apps and Desktops 2109, the 'Virtual channel allow list' policy setting will be enabled by default. This means that custom/third-party virtual channels will no longer work with the default configuration.
The following options are available:
Disable the 'Virtual channel allow list' policy setting to allow all virtual channels again.
Add the Nuance virtual channels to the allow list; for more information, see the Citrix documentation.
For more information, see the Nuance Citrix Extension Deployment and Configuration Guide delivered with the Nuance virtual extension package or contact Nuance Technical Support.
- Be aware that your application must be recompiled following this upgrade.
- In partner integrations based on Dragon Medical SpeechKit (.NET edition), new users without a Nuance PowerMic Mobile license who select PowerMic Mobile from the Current Device menu are notified that they must apply for a license or select another input device. [DNB-17840]
- To display your application's end user online help in the personalization & help window, make sure it can be loaded in an iframe. [DNB-20538]
- The VUI form focus is no longer set to the speech-enabled field when
Initialize(),Open()orSynchronize()is called on the VuiController. [DNB-12643] - Filtering auto-texts (defining filters to deactivate auto-texts selectively) was deprecated in version 3.4 and will no longer work.
- The set of redistributable files was changed in version 3.4. Make sure to verify that all files in the bin folder are included with your application distribution.
- Dragon Medical SpeechKit 2022.3 (.NET edition) is compatible with Dragon Medical Server 2021.x and 2022.x.
- Dragon Medical Server 2022.2 is compatible with client versions 2021.x and 2022.x.
- Microsoft .NET Framework 4.7.2-4.8 and Microsoft Internet Explorer 11 must be installed on all workstations running .NET edition-based applications.
Infrastructure
Infrastructure no longer supported
- Dragon Medical SpeechKit and Dragon Medical Embedded 2022.3 applications do not work with version 2020 servers.
- Version 2020 client applications do not work with version 2022.2 servers.
Infrastructure changes planned for the next release
- Dragon Medical SpeechKit and Dragon Medical embedded 2022.4 and higher will not work with version 2021.1 servers.
- Version 2020.1 client applications will not work with version 2022.3 servers.
System requirements - all clients*
| Component | Recommended | Supported |
|---|---|---|
| Operating system | Windows 11 | Windows 8.1 Windows 10 Windows 11 |
| .NET Framework | Microsoft .NET Framework 4.7.2 | Microsoft .NET Framework 4.7.2-4.8 |
| Web browser | Microsoft Edge WebView2 runtime | Microsoft Edge WebView2 runtime |
Remarks
- Dragon Medical SpeechKit only supports Internet Explorer 10 on platforms for which Internet Explorer 11 is not made available by Microsoft.
System requirements - virtualized environments*
| Component | Recommended | Supported |
|---|---|---|
| Nuance virtual extensions: Client | 122.3.231.0 | 121.1.2121 - 122.3.231.0 |
| VMware Horizon View | VMware Horizon View 7: VMware Horizon View Agent 7.10 or higher VMware Horizon Client 5.2 or higher Protocols: PCoIP, Blast Extreme, Real-Time Audio-Video (RTAV) |
|
| Citrix Virtual Apps and Desktops | Citrix XenApp and XenDesktop: 7.15 or higher Citrix Virtual Apps and Desktops: 1808 or higher |
|
| Citrix Client | Citrix Workspace app: 19.12 or higher | |
| Remote Desktop Services | Windows Server 2019 | Windows Server 2012 R2 Windows Server 2016 Windows Server 2019 |
| Remote Desktop Client | Windows 11 | Windows 8.1 Windows 10 Windows 11 |
| Linux thin clients | Fujitsu Futro | IGEL (For information on the IGEL thin clients supported, search for Nuance compatibility in the IGEL Knowledge Base.) Fujitsu Futro with operating system eLux RP 5.6 (32-bit) and 6.5.2000 or higher (64-bit). |
Supported microphones
Audio works for all microphones listed. Support for button controls is listed below:
| Component | Citrix XenApp | Citrix XenDesktop | RDS | VMware Horizon View |
|---|---|---|---|---|
| Nuance PowerMic 4 | yes* | yes* | yes* | yes* |
| Nuance PowerMic II | yes* | yes* | yes* | yes* |
| Nuance PowerMic II with barcode scanner | yes* | yes* | yes* | yes* |
| Nuance PowerMic III | yes* | yes* | yes* | yes* |
| Philips SpeechMike Air | yes** | yes** | yes** | yes** |
| Philips SpeechMike Premium | yes** | yes** | yes** | yes** |
| Philips SpeechMike Premium Touch | yes** | yes** | yes** | yes** |
| Philips SpeechMike Premium Air | yes** | yes** | yes** | yes** |
| Philips SpeechMike III | yes** | yes** | yes** | yes** |
| Philips SpeechOne PSM6000 headset | yes** | yes** | yes** | yes** |
| Grundig Digta SonicMic II | yes** | yes** | yes** | yes*** |
| Grundig Digta SonicMic II (US edition) | yes** | yes** | yes** | yes*** |
| Grundig Digta SonicMic 3 | yes** | yes** | yes** | yes*** |
* To enable Nuance PowerMic controls, install the Nuance PowerMic Citrix Extension/PowerMic RDS Extension/PowerMic VMware Client Extension.
** To enable button controls for third-party devices, install the corresponding redistributable packages.
*** To enable button controls for these devices, configure USB device splitting.
Remarks
- For more information on virtualized environments, see the Docs & Guidelines folder of the Nuance virtual extensions package on the Nuance Healthcare Development Platform.
- For security reasons, make sure that VDI channel encryption is enabled between client end points and VDI servers or virtual desktops. Disabling encryption in a virtualized environment can lead to PHI being exposed. Encryption is enabled by default.
- Nuance Citrix/RDS/VMware Audio Extension and Nuance PowerMic Citrix/RDS/VMware Extension:
The extensions do not need to be installed on the server/virtual desktop; the required server binaries are already included in the application folder.
Make sure you uninstall the corresponding server/virtual desktop component setup if it is no longer used by other products.
- Nuance RDS Audio Extension and Nuance PowerMic RDS Client Extension: UDP transport must be disabled on Remote Desktop Protocol (RDP) clients.
To disable UDP transport, add the following registry keys and value to the Remote Desktop Client, then restart the PC:
Keys:
HKEY_LOCAL_MACHINE\Software\Microsoft\Terminal Server Client
HKEY_LOCAL_MACHINE\Software\Wow6432Node\Microsoft\Terminal Server Client
DWORD Value:
DisableUDPTransport = 1
- VMware Horizon View 7.10 and higher: RTAV with device splitting is recommended if Nuance audio channels cannot be used.
- To enable microphone button support for Philips and Grundig devices, contact your device vendor for drivers that support your virtualized environment; deploy them on the server/virtual desktop where your application is hosted and on the client PC.
- Microsoft RDS: When the Grundig drivers are not installed on both RDS server and client endpoint, the application using a Grundig device might become unresponsive when reconnecting to a session.
- Philips SpeechMike on Linux thin clients in a Citrix environment: Session reconnect might not work. Solution: Make sure SpeechMike firmware version 2.54 or higher is installed.
System requirements - edit controls*
| Component | Recommended | Supported |
|---|---|---|
| System.Windows.Forms.TextBoxBase System.Windows.Forms.TextBox System.Windows.Forms.MaskedTextBox System.Windows.Forms.RichTextBox | 4.5 | 4.5 |
| System.Windows.Controls.TextBox | 4.5 | 4.5 |
*End-of-life: third-party environments
Support for third-party environments is only valid as long as they are supported by the corresponding vendor and might be subject to other restrictions. Please contact Nuance Technical Support for details. For more information, see the documentation delivered with the third-party product and supporting Nuance documentation.
When standard support by the vendor has stopped, Nuance will continue support if an issue is specific to the Nuance solution, within the limitations of the vendor’s standard end-of-life and Nuance's policy. This means that issues that are a combination of the vendor's component and the Nuance solution cannot be supported.
Dragon Medical SpeechKit product life cycle
Nuance provides support throughout the life cycle of one version and point release. Please note that Nuance will not perform problem analysis after the scheduled start of restricted maintenance. Dragon Medical Server versions released over three months after the dates stated here will not work with these client editions.
| .NET edition | 2020.4 | 2021.4 | 2022.1 | 2022.3 |
|---|---|---|---|---|
| Restricted maintenance (scheduled start) | 2021-12-31 | 2022-12-31 | 2023-03-31 | 2023-07-31 |